Equipment Bollard in a Residential Garage - The Building Code Forum
Oct 20, 2009 · Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab. We also have two alternates that are wheel …
S-1 & S-2 Regarding Parking Garage - The Building Code Forum
Jan 7, 2015 · Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage". Section 311.3 Classifies "Parking garages, open or …
Garage pedestrian door size | The Building Code Forum
Nov 24, 2025 · I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door. will that size be acceptable since it is not the main egress door?
Egress through a garage. | The Building Code Forum
Apr 9, 2015 · A detached garage is not going to require egress in the same manner as a habitable space. How do you egress out of a garage itself?
Pex/pvc pipes in a garage - The Building Code Forum
Jun 11, 2019 · Are pex/ pvc water and waste lines allowed to run (exposed) through a garage? I know the code requires ducts to be min. 26 gage metal, and other penetrations between garage and house …
Garage Step and Slope - The Building Code Forum
Nov 15, 2020 · Garage floor surfaces shall be of approved noncombustible material. The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids …
Minimum Floor Slope for Drainage - The Building Code Forum
Oct 19, 2009 · Irc The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope. It is usually 1/8” to 1/4” per foot. Here is the citation from the …
HVAC in a garage - The Building Code Forum
Jan 12, 2012 · Codes do not permit duct openings in a residential attached garage, for obvious reasons. I ran across one yesterday where it appears that the contractor is placing an air handler in a garage …
Step from garage into House?? | The Building Code Forum
Jul 22, 2019 · I do not see anywhere in the IRC 2015 that requires a step from the garage into the house. I saw the opening penetrations R302.5 & Garage section R309. Is the step still a requirement …
Branch Circuit to Detached Garage - The Building Code Forum
Oct 16, 2009 · An electrical service disconnect is located in or on the main structure. One of the panelboard has a 20A GFCI breaker that is labeled "garage." The garage is detached and the circuit …